# First attempt to SYSGEN; DG RDOS 6.60 distro tape. # Tom Jennings # 24 Feb 2005 R SYSGEN SYS1. NOVA SYSGEN REV 6.60 VALID ANSWERS ARE IN PARENTHESIS RESPOND ACCORDINGLY MAPPED SYSTEM? ("0"=NO "1"=YES) 1 MAXIMUM NUMBER OF CHANNELS BACKGROUND WILL USE(1-255) 20 MAXIMUM NUMBER OF CHANNELS FOREGROUND WILL USE(0-255) 20 NUMBER OF NOVADISK DISK CONTROLLERS(0-2) 0 NUMBER OF 6063/6064 DISK CONTROLLERS(0-2) 0 NUMBER OF 6060/6061/6067/6122 DISK CONTROLLERS(0-2) 0 NUMBER OF OTHER TYPES OF MOVING HEAD DISK CONTROLLERS(0-2) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 NUMBER OF DEVICES FOR CONTROLLER #1(1-4) 1 TOP LOADER(S)? ("0"=NO "1"=YES) 1 ENTER BAD BLOCK POOL SIZE IN BLOCKS (0-512) 24 DUAL PROCESSORS (IPB)? ("0"=NO "1"=YES) 0 ENTER NUMBER OF STACKS (1-10) 5 ENTER NUMBER OF EXTRA CELLS (0-64) 8 TUNING? ("0"=NO "1"=YES) 1 SHALL TUNING BE WITH("1") OR WITHOUT("0") OVERLAY REPORT? 1 ENTER NUMBER OF EXTRA BUFFERS REQUIRED (0-63) 8 MAXIMUM NUMBER OF SUB-DIRECTORIES/SUB-PARTITIONS ACCESSIBLE AT ONE TIME (0-64) 16 ENTER NUMBER OF CONTROLLERS FOR MTA(0-2) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 ENTER NUMBER OF DEVICES FOR CONTROLLER #1 (1-8) 2 ENTER NUMBER OF CONTROLLERS FOR CTA(0-2) 0 AUTO RESTART ON POWER FAIL? ("0"=NO "1"=YES) 0 OPERATOR MESSAGES? ("0"=NO "1"=YES) 1 RTC? ("0"=NO "1"=YES) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 ENTER RTC FREQ (1=10HZ 2=50HZ 3=60HZ 4=100HZ 5=1000HZ) 3 ENTER NUMBER OF PTR(0-2) 0 ENTER NUMBER OF PTP(0-2) 0 ENTER NUMBER OF LPT(0-2) 1 ENTER COLUMN SIZE FOR LPT #1 (80 OR 132) 132 DATA CHANNEL LINE PRINTER? ("0"=NO "1"=YES) 0 ENTER NUMBER OF CDR(0-2) 0 ENTER NUMBER OF PLT(0-2) 0 ENTER NUMBER OF MCA(0-2) 0 QTY? ("0"=NO "1"=YES) 0 ULM? ("0"=NO "1"=YES) 0 ALM? ("0"=NO "1"=YES) 0 SECOND TTY? ("0"=NO "1"=YES) 1 CORE DUMP? ("0"=NO "1"=LPT "2"=MTA "3"=6030 "4"=6097) 2 FILE DOES NOT EXIST: MRDOSA.LB FILE DOES NOT EXIST: MRDOSB.LB FILE DOES NOT EXIST: MRDOSC.LB FILE DOES NOT EXIST: MRDOSI.LB FILE DOES NOT EXIST: MRDOSO.LB R TYPE CLI.CM RLDR/Y/N/P SYS000 SYS1.SV/S ^ MRDOSA.LB MRDOSB.LB BADSP MRDOSC.LB MRDOSI.LB ^ [MRDOSO.LB] SYS1.LM/L DELETE BADSP.RB SYS000.RB R LIST SYS-.- SYS1.LM 0 D SYSGEN.SV 14848 SD SYS.LB 20372 D SYS1.SG 1827 SYS1.SV 0 D SYS5.LB 17326 D R SYSGEN SYS1. NOVA SYSGEN REV 6.60 VALID ANSWERS ARE IN PARENTHESIS RESPOND ACCORDINGLY MAPPED SYSTEM? ("0"=NO "1"=YES) 1 MAXIMUM NUMBER OF CHANNELS BACKGROUND WILL USE(1-255) 20 MAXIMUM NUMBER OF CHANNELS FOREGROUND WILL USE(0-255) 20 NUMBER OF NOVADISK DISK CONTROLLERS(0-2) 0 NUMBER OF 6063/6064 DISK CONTROLLERS(0-2) 0 NUMBER OF 6060/6061/6067/6122 DISK CONTROLLERS(0-2) 0 NUMBER OF OTHER TYPES OF MOVING HEAD DISK CONTROLLERS(0-2) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 NUMBER OF DEVICES FOR CONTROLLER #1(1-4) 1 TOP LOADER(S)? ("0"=NO "1"=YES) 1 ENTER BAD BLOCK POOL SIZE IN BLOCKS (0-512) 24 DUAL PROCESSORS (IPB)? ("0"=NO "1"=YES) 0 ENTER NUMBER OF STACKS (1-10) 5 ENTER NUMBER OF EXTRA CELLS (0-64) 8 TUNING? ("0"=NO "1"=YES) 1 SHALL TUNING BE WITH("1") OR WITHOUT("0") OVERLAY REPORT? 1 ENTER NUMBER OF EXTRA BUFFERS REQUIRED (0-63) 8 MAXIMUM NUMBER OF SUB-DIRECTORIES/SUB-PARTITIONS ACCESSIBLE AT ONE TIME (0-64) 32 ENTER NUMBER OF CONTROLLERS FOR MTA(0-2) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 ENTER NUMBER OF DEVICES FOR CONTROLLER #1 (1-8) 1 ENTER NUMBER OF CONTROLLERS FOR CTA(0-2) 0 AUTO RESTART ON POWER FAIL? ("0"=NO "1"=YES) 0 OPERATOR MESSAGES? ("0"=NO "1"=YES) 1 RTC? ("0"=NO "1"=YES) 1 DEVICE PRIMARY("0") OR SECONDARY("1")? 0 ENTER RTC FREQ (1=10HZ 2=50HZ 3=60HZ 4=100HZ 5=1000HZ) 3 ENTER NUMBER OF PTR(0-2) 0 ENTER NUMBER OF PTP(0-2) 0 ENTER NUMBER OF LPT(0-2) 0 ENTER NUMBER OF CDR(0-2) 0 ENTER NUMBER OF PLT(0-2) 0 ENTER NUMBER OF MCA(0-2) 0 QTY? ("0"=NO "1"=YES) 0 ULM? ("0"=NO "1"=YES) 0 ALM? ("0"=NO "1"=YES) 0 SECOND TTY? ("0"=NO "1"=YES) 1 CORE DUMP? ("0"=NO "1"=LPT "2"=MTA "3"=6030 "4"=6097) 0 FILE DOES NOT EXIST: MRDOSA.LB FILE DOES NOT EXIST: MRDOSB.LB FILE DOES NOT EXIST: MRDOSC.LB FILE DOES NOT EXIST: MRDOSI.LB FILE DOES NOT EXIST: MRDOSO.LB R