Link an ActiveX Check Box to a Drop-Down Form Field in Word 2013
Question details
Link an ActiveX check box to a drop-down form field so that checking or clearing the box triggers a defined change.

- Product
- Microsoft Word 2013
- Device & OS
- not provided
- Scenario
- A form author wants a check box selection to control the behavior or value of a drop-down field.
- Observed behavior
- Word does not automatically link the ActiveX check box to the drop-down form field.
Decide what checking and clearing the box should do, and identify whether the drop-down is a legacy form field or an ActiveX combo box. If the Developer tab is hidden, enable it under File > Options > Customize Ribbon.
Change a Legacy Drop-Down Selection with a Check Box Click Event
Use this example when a legacy drop-down should select its first item when the check box is checked and its second item when it is cleared.
An ActiveX check box and a legacy drop-down form field do not link automatically. The example below changes the drop-down selection; it does not enable, disable, or populate the field.
On the Developer tab, use Legacy Tools to insert or select a legacy Drop-Down Form Field. Open its Properties, add at least two items, and set its bookmark name to DropDown1.
Use Developer > Legacy Tools to insert an ActiveX Check Box. Turn on Design Mode, select the check box, and open Properties to confirm its name is CheckBox1.
While Design Mode is on, double-click the check box to open its Click event in the VBA editor. Add the following code inside the generated event procedure: If CheckBox1.Value = True Then ActiveDocument.FormFields("DropDown1").DropDown.Value = 1 Else ActiveDocument.FormFields("DropDown1").DropDown.Value = 2 End If
Save the document as a Word Macro-Enabled Document (.docm), exit Design Mode, and check and clear the box. Confirm that the drop-down switches between its first and second items. Enable macros only if you trust the document.

Edit Word Documents with WPS Writer
WPS Office is a free, lightweight alternative with a familiar interface for opening and editing Word documents. It can help you move everyday document work to WPS, but it does not directly fix Word's ActiveX or VBA behavior.

Frequently Asked Questions
Why doesn't the check box control the drop-down automatically?
The ActiveX check box and legacy drop-down are separate controls. You must define the desired behavior and add code, such as a Click event, to update the drop-down.
How do I find the legacy drop-down's name?
Select the drop-down and open its Properties from the Developer tab. Use the bookmark name shown there in the VBA FormFields reference.
Can the check box enable an ActiveX combo box instead?
Yes. An ActiveX combo box has an Enabled property that VBA can change in the check box's Click event. Insert or select the combo box through Developer > Legacy Tools and check its name in Design Mode before writing the event.
Why does the code stop working after I save the document?
Save it as a Word Macro-Enabled Document (.docm) so the VBA code is retained. When reopening it, check Word's security prompt and enable macros only if you trust the document.