Restart Word SEQ Label Numbering After the Previous Batch
Question details
Continue sequential label numbering from one higher than the previous batch’s highest number.

- Product
- Microsoft Word
- Device & OS
- not provided
- Scenario
- A document uses SEQ fields to number a batch of 18 printed labels.
- Observed behavior
- After printing labels numbered 1 through 18, the next batch should begin at 19 instead of restarting at 1.
In Word, press Alt+F9 to inspect the SEQ field codes and identify the sequence name and the field containing the \r restart switch. Confirm the highest number printed in the previous batch and how many labels the next batch contains.
Change the SEQ restart value manually
Use this method when you know the last number printed and want to prepare the next batch.
Open the label document in Word and press Alt+F9. Find the first label’s SEQ field with a restart switch, such as { SEQ Label \r 1 }.
Edit the number after \r to one more than the highest number in the previous batch. For example, change \r 1 to \r 19 after printing labels 1 through 18.
Press Alt+F9 to show field results, then press Ctrl+A and F9 to update the document fields. Check that the labels run from 19 through 36 before printing.
Use File > Save to retain the changed field code. After the next print run, repeat the process using the next number after the highest label actually printed.
Advance a fixed 18-label sequence with a Word macro
Use this macro after each successful print run when the document always contains exactly 18 sequential labels.
Work with Word label documents in WPS Office
WPS Office is a free, lightweight alternative with a familiar interface for working with Word documents. Open compatible files and move between office suites easily; the Word-specific VBA macro above is not a WPS fix.

Frequently Asked Questions
What does the \r switch do in a Word SEQ field?
The \r switch resets a sequence to the number that follows it. For example, { SEQ Label \r 19 } starts the Label sequence at 19 when the field is updated.
How do I see the SEQ field codes instead of the label numbers?
In Word, press Alt+F9 to toggle between field codes and their displayed results. Press it again to return to the numbers.
What should I do if the number of labels changes?
Check the highest number actually printed, then edit the first SEQ field’s \r value to the next number. The example macro adds 18 and is intended only for a fixed 18-label batch.
Can I use an Excel list to number Word labels?
Yes. Create a serial-number column in Excel, then use Word’s Mailings > Start Mail Merge > Labels and select the workbook as the recipient list. Insert the serial-number merge field into the labels.